Myocardial infarction during adenosine stress test.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 11796565.
- Also identified by PMC identifier 1767004.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A 65 year old woman with history of ischaemic heart disease underwent standard adenosine stress test for myocardial perfusion imaging. She sustained inferior myocardial infarction during the final stages of the stress test. She was admitted to the coronary care unit and received thrombolytic treatment. The patient made an uneventful recovery. Adenosine is widely used for myocardial stress imaging tests and has a good safety profile. So far there has been only one other reported myocardial infarction during adenosine stress test, which was under special circumstances because three days before the test the patient had undergone percutaneous transluminal coronary angioplasty when a severe circumferential dissection was noted. The present patient's case highlights the need to be aware of rare but potentially serious complications of adenosine, even though it generally has an excellent safety record for use in myocardial stress testing.
Medical subject headings
- Adenosine
- Myocardial Infarction
- Vasodilator Agents