Carbon dioxide embolism during minimally invasive vein harvesting.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 11834033.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Gas embolism is a known complication of minimal access procedures in which carbon dioxide insufflation is used. We report a case of significant venous and right heart gas embolization, which occurred during performance of routine minimally invasive vein harvesting. This was manifest by hemodynamic deterioration secondary to transmission by a patent foramen ovale into the left heart and coronary circulation. Techniques to predict, diagnose, and prevent this rare but potentially fatal complication of minimally invasive vein harvesting are suggested.