Cardiac function: MR evaluation in one breath hold with real-time true fast imaging with steady-state precession.

Lee, Vivian S; Resnick, Daniel; Bundy, Jeffrey M; Simonetti, Orlando P; Lee, Peter; Weinreb, Jeffrey C · Radiology · 2002

case_control · Level III

Where this comes from

Abstract

In 12 healthy volunteers and eight patients with cardiac disease, cine magnetic resonance (MR) imaging in the heart was performed with real-time true fast imaging with steady-state precession (FISP), which permitted evaluation of the entire left ventricle in one breath hold (91 msec per frame, 13 frames per section position, nine short-axis section positions per breath hold). Contrast-to-noise ratios (CNRs) and left ventricular mass and function measurements with this technique were compared in all subjects with single-section true FISP imaging and, in the volunteers only, with segmented fast low-angle shot (FLASH) MR imaging. Myocardium-to-blood CNR was significantly higher for both true FISP sequences compared with the FLASH sequence. Measurements of resting left ventricular function with real-time true FISP imaging were comparable with those derived from a series of separate breath-hold single-section true FISP acquisitions.