The influence of remifentanil on the dynamic relationship between sevoflurane and surrogate anesthetic effect measures derived from the EEG.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 11873028.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The authors modeled the influence of remifentanil on the dynamics of sevoflurane using three parameters derived from the electroencephalogram: 95% spectral edge frequency (SEF), canonical univariate parameter (CUP), and Bispectral Index (BIS). Thirty-six patients with American Society of Anesthesiologists physical status class I or II were recruited, of which 12 received a target remifentanil concentration of 0 ng/ml, eight 2 ng/ml, eight 4 ng/ml, and another eight 8 ng/ml. Next (before surgery), several step-wise changes in the end-tidal sevoflurane concentration (F(ET,sevo)) were performed. A data acquisition system simultaneously recorded F(ET,sevo), the raw electroencephalogram, BIS, and SEF. The authors used a combination of an effect compartment and an inhibitory sigmoid E(MAX) model to describe the relation between F(ET,sevo) and BIS, SEF, and CUP. Model parameters (t(1/2)k(e0), E(MAX), E(MIN), C(50), gamma, CUP weight factors) were estimated using the population data analysis program NONMEM. Significant remifentanil model parameter dependencies (P < 0.01) were determined. Determined from SEF, remifentanil had no effect on t(1/2)k(e0) (1.91 +/- 0.26 min [mean +/- standard error]) but caused an increase in C(50) (baseline = 1.48 +/- 0.12%; 80% increase at 8 ng/ml) and decrease in E(MIN) (baseline = 10.8 +/- 0.6 Hz; 80% reduction at 8 ng/ml). Determined from CUP, remifentanil caused a dose-dependent decrease in t(1/2)k(e0) (baseline = 4.31 +/- 1.00 min; 60% decrease at 8 ng/ml), with no effect on C(50) (baseline = 0.88 +/- 0.13%). Determined from BIS, remifentanil caused a dose-dependent decrease in t(1/2)k(e0) (baseline value = 3.11 +/- 0.32 min; 40% decrease at 8 ng/ml), without affecting C(50) (baseline = 1.12 +/- 0.05%). Median R(2) values of the pooled data set were 0.815 for SEF, 0.933 for CUP (P < 0.01 vs. SEF), and 0.952 for BIS (P < 0.01 vs. SEF and CUP). Addition of remifentanil increased the R(2) values for CUP only. Remifentanil accelerates sevoflurane blood-brain equilibration without affecting its hypnotic potency as determined from BIS and CUP. In terms of R(2), the authors' pharmacodynamic model describes the anesthetic-BIS relation best.
Medical subject headings
- Anesthesia, Inhalation
- Anesthetics, Inhalation
- Anesthetics, Intravenous
- Electroencephalography
- Methyl Ethers
- Piperidines