Frozen autografts: an alternative to graft disposal.

Cowey, Alex; Clough, T; Hirst, P · Knee · 2002

case_report · Level V

Where this comes from

Abstract

The use of fresh frozen tendon allografts is a well-documented surgical technique. We present a case where a harvested semitendinosus autograft was preserved by deep-freezing, having abandoned the initial procedure due to infection. After treatment of the infection the graft was subsequently used to reconstruct the postero-lateral corner complex with no deleterious effect at 1 year.

Medical subject headings

Anatomy