Implantation of the permanent Jarvik-2000 left ventricular assist device: a single-center experience.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 12039489.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We sought to evaluate the surgical results and effects of continuous support with the permanent Jarvik-2000 left ventricular assist device (LVAD). We report the early outcomes. A shortage of transplant donors necessitates the testing of alternative treatments. The Jarvik-2000 is an axial flow pump with a percutaneous retro-auricular power connector, designed for permanent use. Patients with severe heart failure (HF), unsuitable for heart transplantation or conventional LVAD support, were offered implantation. The surgical approach included a left lateral thoracotomy. The device was implanted into the left ventricular apex on femoro-femoral bypass. It is set to allow pulsatile flow with an aortic valve opening. Anticoagulation is adjusted the same as for patients with a heart valve. Between May 2001 and August 2001, we implanted the Jarvik-2000 in two patients with dilated cardiomyopathy and in one with cardiac amyloidosis, all with severe HF (cardiac index 1.8 +/- 0.3 l/m(2) per min). One patient required preoperative inotropic support. All patients did well, with no repeat operations or infections. Patients received 4.3 +/- 3.2 packed red blood cells and were intubated at 14 +/- 3 h, and the intensive care unit stay was 7.0 +/- 0.5 days. The cardiac index increased from 3.7 +/- 1.5 l/min per m(2) at 8,000 rpm to 5.9 +/- 2.9 l/min per m(2) at 12,000 rpm. All patients currently have mild hemolysis not requiring transfusion. The following postoperative events were recorded: a transient ischemic attack with complete recovery, a short re-intubation due to ventricular arrhythmia, loss of consciousness with a battery change while standing, knee-joint effusion after ergometry training, a minor wound problem and a short hospital re-admission due to dehydration. Patients were discharged home after 49 +/- 7 days; one has returned to work. All quality-of-life scores have improved. The permanent Jarvik-2000 appears safe. It can be used for dilative or restrictive disease. The Jarvik-2000 might prove a valid option for the long-term treatment of patients with severe HF.
Medical subject headings
- Amyloidosis
- Cardiomyopathy, Dilated
- Heart Diseases
- Heart-Assist Devices