Ex vivo PMA-induced respiratory burst and TNF-alpha secretion elicited from inflammatory cells on machined and porous blood plasma clot-coated titanium.

Jansson, Eva; Källtorp, Mia; Thomsen, Peter; Tengvall, Pentti · Biomaterials · 2002

basic_science · Level V

Where this comes from

Abstract

The release of inflammatory mediators around implants and normal wounds may differ due to the presence of the solid surface. In this study, machined and sub-micron porous titanium implants with and without a 100 nm thick blood plasma clot were inserted subcutaneously in rat for 3 or 24 h. The cell recruitment to the interfaces, in vivo secretion of TNF-alpha and the ex vivo PMA-induced production of reactive oxygen species were subsequently investigated. The thin plasma clot coating gave rise to an increased ex vivo PMA-stimulated oxygen radical production by implant-associated cells at both implantation times, and an increased cell recruitment at 24 h. The total TNF-alpha secretion was highest at sham sites and plasma clot-coated porous titanium at 24 h. After 24 h, the cell-type pattern in the exudate around the porous plasma-coated implant was more similar to that found at sham sites than that adjacent to the non-coated implants. No differences were observed between the machined Ti and the machined sub-micron porous Ti.

Medical subject headings