The release of inflammatory mediators around implants and normal wounds may differ due to the presence of the solid surface. In this study, machined and sub-micron porous titanium implants with and without a 100 nm thick blood plasma clot were inserted subcutaneously in rat for 3 or 24 h. The cell recruitment to the interfaces, in vivo secretion of TNF-alpha and the ex vivo PMA-induced production of reactive oxygen species were subsequently investigated. The thin plasma clot coating gave rise to an increased ex vivo PMA-stimulated oxygen radical production by implant-associated cells at both implantation times, and an increased cell recruitment at 24 h. The total TNF-alpha secretion was highest at sham sites and plasma clot-coated porous titanium at 24 h. After 24 h, the cell-type pattern in the exudate around the porous plasma-coated implant was more similar to that found at sham sites than that adjacent to the non-coated implants. No differences were observed between the machined Ti and the machined sub-micron porous Ti.
Medical subject headings
- Biocompatible Materials
- Respiratory Burst
- Tetradecanoylphorbol Acetate
- Titanium