Three-dimensional volumetric interpolated breath-hold MR imaging for whole-body tumor staging in less than 15 minutes: a feasibility study.

Lauenstein, Thomas C; Goehde, Susanne C; Herborn, Christoph U; Treder, Wiebke; Ruehm, Stefan G; Debatin, Jörg F; Barkhausen, Jörg · AJR Am J Roentgenol · 2002

cross_sectional · Level IV

Where this comes from

Abstract

The purpose of our study was to evaluate the feasibility and accuracy of three-dimensional (3D) volumetric interpolated breath-hold whole-body MR imaging using CT and nuclear medicine techniques as the standard of reference in patients with metastases. The 3D volumetric interpolated breath-hold whole-body MR imaging examination for metastases screening correlates well with CT and scintigraphy. The use of the rolling table platform permits rapid whole-body imaging in an average of 11 min. The preliminary results indicate that the described technique has the potential to emerge as an all-encompassing alternative to conventional multimodality tumor staging strategies.

Medical subject headings