Comparison of tension-band and figure-of-eight wiring techniques for treatment of olecranon fractures.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 12195257.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Two different internal fixation techniques for closed displaced fractures of the olecranon were evaluated at a mean of 18 years after injury. Thirty-two of the patients received tension-band wiring, and 35 received figure-of-eight wiring. There were 41 women (mean age, 52 years) and 26 men (mean age, 32 years) included. The results revealed that 80% of the patients had no subjective complaints, 16% had occasional pain, and 4% had daily pain. Comparison of the injured and uninjured elbows demonstrated a 3 degrees reduction of flexion (P <.05) and a 5 degrees loss of extension (P <.01). More than 50% of the fractured elbows had degenerative changes (joint space narrowing, subchondral cysts, subchondral sclerosis, and osteophytes) (P <.001), and 4 had osteoarthritis (P <.05). No subjective, objective, or radiographic differences were found when the two techniques were compared. Removal of the hardware was performed in 81% of the patients with tension-band wiring and in 43% of the patients with figure-of-eight wiring (P <.01). The figure-of-eight technique can, therefore, be recommended, as it is associated with less frequent secondary procedures for hardware removal.
Medical subject headings
- Bone Wires
- Elbow Joint
- Fracture Fixation, Internal
Anatomy
- elbow