Treatment of superior vena cava obstruction secondary to pacemaker wires with balloon venoplasty and insertion of metallic stents.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 12208227.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Pacemaker wires can result in stenosis of the superior vena cava and other central veins. The aim of this study is to demonstrate the safety and effectiveness of treating stenoses of the superior vena cava (SVC) and central veins with balloon venoplasty and metallic stent insertion in the presence of cardiac pacemaker wires. Three patients were referred to the department after developing symptomatic SVC obstruction following implantation of a cardiac pacemaker several years earlier. They were examined with duplex ultrasound and venography, which revealed significant stenoses of the central veins. These patients subsequently underwent endovascular treatment which involved balloon dilation and stent insertion. The treatment was successful in all three patients, without any complications. Long-term patency of up to 4 years is recorded. No pacemaker function dysfunction was encountered. SVC stenting is safe and effective in patients who develop the SVC obstruction after cardiac pacemaker insertion.
Medical subject headings
- Angioplasty, Balloon
- Pacemaker, Artificial
- Stents
- Superior Vena Cava Syndrome