This study sought to determine the predicted Cp50 of propofol required for laryngeal mask airway insertion (Cp50LMA) and to investigate whether nitrous oxide reduces these required concentrations. Using target-controlled infusion and incorporating the standard Diprifusor pharmacokinetic model, 46 unpremedicated patients were randomly assigned to one of two groups. The patients received either 40% oxygen in air (control group: n = 23), or 60% nitrous oxide in oxygen (nitrous oxide group: n = 23). The target concentration for each patient was determined using the up and down method. Following equilibration between the predetermined blood and effect site concentrations, had been established for > 10 min, laryngeal mask airway insertion was attempted without neuromuscular relaxants. The data were analysed using a probit analysis to obtain Cp50LMA levels. The values for Cp50LMA were 3.24 micro g.ml-1 in the control group and 1.93 microg.ml-1 in the nitrous oxide group.