Successful airway stenting using silicone prosthesis for esophagobronchial fistula.

Miwa, Keisuke; Mitsuoka, Masahiro; Tayama, Kohsuke; Tomita, Naofumi; Takamori, Shinzo; Hayashi, Akihiro; Shirouzu, Kazuo · Chest · 2002

case_report · Level V

Where this comes from

Abstract

We present the case of a 55-year-old man with advanced esophageal cancer who was successfully treated using a self-expandable metallic stent (S-EMS) for 6 months and subsequently was treated for an esophagobronchial fistula as a complication of the initial S-EMS using a silicone airway stent for an additional 4 months. This is the first report in the literature concerning penetration into the airway of an S-EMS implanted in the esophagus. The present case suggests that airway stenting using a silicone stent as treatment for an esophagobronchial fistula may represent a useful modality.

Medical subject headings