Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: effect on image quality.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 12388481.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We hypothesized that radiation doses for abdominal CT could be reduced by adjusting the dose for a patient's weight and cross-sectional abdominal dimensions, with the resultant scans still being of diagnostic quality. Using a multidetector CT scanner, we prospectively studied 39 patients who were 65 years and older who had a known history of cancer. After performing a diagnostic contrast-enhanced CT examination, we obtained four slices each (centered at the top of the right kidney) at a standard radiation dose (240-300 mA) and at a 50% reduced dose (120-150 mA) at a constant kilovoltage of 140. Scans were obtained during a single breath-hold, with a 2.5-mm detector configuration and a slice pitch of 6:1. Reconstructed slice thickness was 5 mm. In a blinded review, two radiologists rated the randomized CT scans for overall image quality and anatomic details of liver, spleen, adrenal glands, kidneys, pancreas, and abdominal wall, using a 5-point scale (1 = unacceptable, 2 = substandard, 3 = acceptable, 4 = above average, and 5 = superior). Patients' weight and abdominal circumference, area, and anteroposterior and transverse diameters were correlated with image quality of scans obtained at standard-dose and 50% reduced-dose CT. Statistical analysis of the data was performed using Wilcoxon's signed rank test. Overall, the image quality score was significantly higher (p < 0.005) on the scans obtained with standard-dose CT. No statistically significant difference in image quality was noted in the 50% reduced- and standard-dose CT scans in patients who weighed less than 180 lb, or 81 kg, (p > 0.05) and who had a transverse abdominal diameter of less than 34.5 cm (p > 0.05), an anteroposterior diameter of less than 28 cm (p > 0.05), a cross-sectional circumference of less than 105 cm (p > 0.05), and a cross-sectional area of less than 800 cm(2) (p > 0.05). Good interobserver agreement (p > 0.5) was found between the two reviewing radiologists. Abdominal CT scan quality appears to be acceptable even with a 50% reduction in radiation dose except in patients with large anthropometric measurements. A reduction in CT radiation dose is possible if the tube current is optimized for the patient's weight and abdominal dimensions.
Medical subject headings
- Neoplasms
- Radiography, Abdominal
- Tomography, X-Ray Computed