Learning to apply effective cricoid pressure using a part task trainer.
other · Level V
Where this comes from
- Record sourced from PubMed, PMID 12392458.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
An anatomically-correct model of a larynx inside a head and neck model was constructed so that the location, direction and amount of force applied to the neck could be measured. Fifty trained staff from three general hospitals were then asked to apply cricoid pressure on the model. None was able to state the force that should be applied (30 N), and only five (10%) actually applied cricoid pressure effectively. After training using the model, 45 (90%) applied cricoid pressure correctly (p < 0.001). This study demonstrates that improved training in cricoid pressure is needed and supports earlier researchers who suggested that this can be achieved using simulators.
Medical subject headings
- Anesthesiology
- Cricoid Cartilage
- Education, Medical, Graduate
- Intubation, Intratracheal
- Manikins