A comparison between the Farr radioimmunoassay and a new automated fluorescence immunoassay for the detection of antibodies against double stranded DNA in serum.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 12429543.
- Also identified by PMC identifier 1753959.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To compare test characteristics of the Farr radioimmunoassay and an automated fluorescence immunoassay (ELIA dsDNA test) for the diagnosis of systemic lupus erythematosus (SLE). A cross sectional study comprising 440 samples from 440 patients, sent to the laboratory over a three month period for anti-dsDNA testing. Chart review was performed, blinded for test results, to count for each patient the number of American College of Rheumatology criteria for the classification of SLE that were fulfilled. At least four criteria were met by 248 (56%) patients (SLE), one to three criteria by 77 (18%) (lupus-like disease, LLD), and no criterion by 115 (26%) (non-SLE/non-LLD). Results from serum samples from the non-SLE/non-LLD and SLE groups were used to calculate receiver operating characteristic curves. For the Farr assay, specificities of 95% and 99% corresponded to sensitivities of 72% and 56% respectively. For the ELIA dsDNA test these levels of specificity corresponded to sensitivities of 44% and 17% respectively. The Farr radioimmunoassay is superior to the ELIA dsDNA test for identifying patients with SLE.
Medical subject headings
- DNA
- Fluorescent Antibody Technique
- Lupus Erythematosus, Systemic
- Radioimmunoprecipitation Assay