A comparison of lactated ringer's solution to hydroxyethyl starch 6% in a model of severe hemorrhagic shock and continuous bleeding in dogs.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 12505920.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
In this randomized, controlled study in dogs, we examined the short-term effects of blood pressure targeted fluid resuscitation with colloids or crystalloids solutions on systemic oxygen delivery, and lactate blood concentration. Fluid resuscitation using hydroxyethyl starch (HES) 6% to a mean arterial blood pressure (MAP) of 60 mm Hg was compared with lactated Ringer's solution (LR) to a MAP of 60 or 80 mm Hg (LR60 and LR80, respectively). The model was one of withdrawal of blood to a MAP of 40 mm Hg through an arterial catheter that was then connected to a system allowing bleeding to occur throughout the study whenever MAP exceeded 40 mm Hg. Target MAP was maintained for 60 min with a continuous infusion of the designated fluid replacement. All 15 dogs (5 in each group) survived until the last measurement. Blood loss in the LR80 group (2980 +/- 503 mL) (all values mean +/- SD) was larger than in the LR60 and HES60 groups (1800 +/- 389 mL, and 1820 +/- 219 mL, respectively) (P < 0.001). Whereas 840 +/- 219 mL of HES60 was needed to maintain target MAP, 1880 +/- 425 mL of LR was needed in the LR60 group, and 4590 +/- 930 mL in the LR80 group (P < 0.001). Lactate blood concentrations were smaller and delivered O(2) higher in the HES60 group (35 +/- 17 mg/dL and 239 +/- 61 mL/min, respectively) in comparison to the LR60 group (89 +/- 18 mg/dL and 140 +/- 48 mL/min, respectively) and the LR80 group (75 +/- 23 mg/dL and 153 +/- 17 mL/min, respectively) (P = 0.02 and P = 0.026). In conclusion, fluid resuscitation during uncontrolled bleeding, to a target MAP of 60 mm Hg, using HES60 resulted in larger oxygen delivery and smaller systemic lactate A resuscitation to a target MAP of 60 or 80 mm Hg using LR. Fluid resuscitation to a target mean arterial blood pressure of 60 mm Hg during uncontrolled bleeding resulted in larger oxygen delivery and smaller systemic lactate concentrations when hydroxyethyl starch 6% was used, in comparison to lactated Ringer's solution resuscitation to a target mean arterial blood pressure of 60 or 80 mm Hg.
Medical subject headings
- Hemorrhage
- Hydroxyethyl Starch Derivatives
- Isotonic Solutions
- Plasma Substitutes
- Shock, Hemorrhagic