Human serum albumin incorporating synthetic heme: red blood cell substitute without hypertension by nitric oxide scavenging.

Tsuchida, Eishun; Komatsu, Teruyuki; Matsukawa, Yasuko; Nakagawa, Akito; Sakai, Hiromi; Kobayashi, Koichi; Suematsu, Makoto · J Biomed Mater Res A · 2003

Where this comes from

Abstract

The administration of extracellular, hemoglobin-based oxygen carriers often elicits an acute increase in blood pressure by vasoconstriction. This side effect is now recognized to be due to the depletion of nitric oxide (endothelial-derived relaxing factor) by the extravasuated hemoglobins. We have recently found that the administration of a recombinant human serum albumin (rHSA)-based oxygen carrier involving synthetic tetraphenyporphinatoiron(II) derivative (FeP) (rHSA-FeP) does not induce such hypertensive action, because of its low permeability through the vascular endothelium. The heart rate responses after the rHSA-FeP injection were also negligibly small. Visualization of the intestinal microcirculatory changes clearly revealed the widths of the venule and arteriole to be fairly constant. The entirely synthetic rHSA-FeP becomes a promising material as a new type of red blood cell substitute.