Dislocated wrap after previous reduction aortoplasty causes erosion of the ascending aorta.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 12607683.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We report a patient with bicuspid aortic valve and dilatation of the ascending aorta who had previous aortic valve replacement and reduction aortoplasty with wrapping. After 4 years, reoperation because of coronary artery disease and paravalvular leakage revealed an erosion of the aortic wall due to dislocation of the wrap. This complication confirms the need for secure anchoring and good fitting of the Dacron wrap to avoid alterations of the underlying aortic wall.
Medical subject headings
- Aorta
- Aortic Valve
- Cardiac Surgical Procedures
- Prostheses and Implants