Reduction of electromyographic noise in the signal-averaged electrocardiogram by spectral decomposition.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 12617532.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This paper proposes a technique to improve the quality of high-resolution electrocardiogram by weighting the coherent average of beats by a function of the energy of the corrupting myoelectric noise, prior to subsequent detection of ventricular late potentials. The results obtained with 20 patients indicate the method requires fewer beats than conventional nonweighted average to achieve the same noise level.
Medical subject headings
- Algorithms
- Artifacts
- Electrocardiography
- Electromyography
- Models, Biological
- Signal Processing, Computer-Assisted