A reusable suture anchor for arthroscopy psychomotor skills training.
expert_opinion · Level V
Where this comes from
- Record sourced from PubMed, PMID 12627137.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
For residents to adequately develop the early arthroscopy psychomotor skills required to better learn how to manage the improvisational situations they will encounter during actual patient cases, they need to experience sufficient practice repetitions within a contextually relevant environment. Unfortunately, the cost of suture anchors can be a practice repetition-limiting factor in learning arthroscopic knot-tying techniques. We describe a technique for creating inexpensive reusable suture anchors and provide an example of their application to repair the anterior glenoid labrum during an arthroscopy psychomotor skills laboratory training session.
Medical subject headings
- Arthroscopy
- Orthopedics
- Psychomotor Performance
- Suture Techniques
Anatomy
- scapula