Normal jugular bulb oxygen saturation.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 12754351.
- Also identified by PMC identifier 1738484.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Normal values of the jugular bulb oxygen saturation were obtained in 1942 and in 1963. Correct catheter positioning was not confirmed radiologically. To replicate the measurements during angiographic catheterisation of the jugular bulb. Oxygen saturation in the jugular bulb (SjO(2)), inferior petrosal sinus (SipsO(2)), and internal jugular vein was bilaterally measured in 12 patients with Cushing's syndrome undergoing selective bilateral catheterisation of the inferior petrosal sinus. In addition, data from the two old series were reanalysed for comparison. SjO(2) values (44.7%) were significantly lower than in the two old series, particularly concerning the normal lower limit (54.6% and 55.0% respectively). Comparative analysis suggests that contamination with the extracerebral blood of the facial veins and inferior petrosal sinuses was responsible for falsely high SjO(2) values in the two old series. The normal lower SjO(2) limit is lower than previously recognised. This may have practical implications for treating severe head trauma patients.
Medical subject headings
- Glomus Jugulare
- Oxygen