Safety of inhaled corticosteroids delivered by plastic and metal spacers.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 12765924.
- Also identified by PMC identifier 1763135.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Because of its non-electrostatic properties the metal Nebuchamber (NC) valved holding chamber (VHC) delivers a greater mass of aerosol to the mouth than the polypropylene Aerochamber (AC) VHC. Delivery of more aerosol to the lungs may also increase systemic absorption of inhaled corticosteroids (ICS) and hypothalamo-pituitary-adrenal (HPA) suppression. Thirty children (mean 4.3 (SD 0.3) years) received 200 micro g budesonide twice daily by NC or AC, both with the mask provided, in a randomised, two month crossover trial. Twenty four hour urinary free cortisol (UFC) was determined as a measure of HPA suppression. UFC decreased from 42.3 (7.8) nmol UFC/nmol creatinine control to 26.2 (2.4) (p = 0.06 v control) after AC, and to 24.5 (2.5) (p = 0.04 v control) after NC (p = 0.4 AC v NC). Despite a greater total dose delivered to the mouth, NC is not associated with greater HPA suppression when using 400 micro g/day budesonide under real life conditions in young children.
Medical subject headings
- Anti-Inflammatory Agents
- Asthma
- Bronchodilator Agents
- Budesonide
- Inhalation Spacers