Collar osteophytes: a cause of false-positive findings in bone scans for hip fractures.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 12818858.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A retrospective review of our radiology database revealed five elderly patients, seen over a 12-month period, whose findings were judged positive for hip fractures on the basis of their bone scans, but whose MR imaging findings were negative. The presence of collar osteophytes around the femoral neck caused a false diagnosis of hip fracture for these patients, as revealed on radionuclide bone scans. CT or MR imaging correlation is needed where collar osteophytes may have caused an incorrect diagnosis of hip fracture based on a bone scan.
Medical subject headings
- Femoral Neck Fractures
- Tomography, Emission-Computed, Single-Photon