Hip-vagina fistula after acetabular revision.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 12820103.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A case of a fistula between the hip and the vagina in a 46-year-old woman after acetabular revision for a failed total hip arthroplasty (THA) is presented. This patient had undergone multiple revision procedures complicated by infection after a primary THA failed because of chronic recurrent dislocation. The patient 18 months after reconstruction of a pelvic discontinuity using an antiprotrusio cage. The chief complaint was weight-bearing groin pain and persistent atypical vaginal discharge. Plain radiographs showed a fracture of the antiprotrusio cage with medial and superior migration of the acetabular cage into the pelvis. An arthrogram showed a fistula between the hip joint and the vagina. To our knowledge, a hip-vaginal fistula has not been reported previously as a complication of THA.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Vaginal Fistula
Anatomy
- hip
- pelvis