Structure and process quality illustrated by fibreoptic intubation: analysis of 1612 cases.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 12859463.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this investigation was the description of structure and process quality based on the analysis of 1612 fibreoptic intubations. We evaluated all fibreoptic intubations (nasotracheal in awake patients and orotracheal in anaesthetised patients) from a previously described database over a period of 2 years. We assessed structure quality by evaluating the distribution of the fibreoptic intubations across all staff anaesthetists, and process quality by analysing the number of attempts, the time required, the cases where we had to switch to conventional intubation and the complications. In all, 955 nasotracheal and 657 orotracheal intubations were evaluated. Almost all anaesthetists performed at least 15 nasotracheal and 10 orotracheal intubations. The success rate was 85.2% at the first attempt. Within 3 min, 93.9% of all fibreoptic intubations were successfully completed. In 24 cases, fibreoptic intubation was abandoned. Severe nasal bleeding as a major complication occurred in 1.3% of the nasotracheal intubations.
Medical subject headings
- Clinical Competence
- Fiber Optic Technology
- Intubation, Intratracheal
- Quality of Health Care