T-wave alternans negative coronary patients with low ejection and benefit from defibrillator implantation.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 12867114.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
In a trial of prophylactic implantation of a defibrillator, a mortality benefit was seen among patients with previous myocardial infarction and a left-ventricular ejection fraction of 0.30 or less. We identified 129 similar patients from two previously published clinical trials in which microvolt T-wave alternans testing was prospectively assessed. At 24 months of follow-up, no sudden cardiac death or cardiac arrest was seen among patients who tested T-wave alternans negative, compared with an event rate of 15.6% among the remaining patients. Testing of T-wave alternans seems to identify patients who are at low risk of ventricular tachyarrhythmic event and who may not benefit from defibrillator therapy.
Medical subject headings
- Defibrillators, Implantable
- Myocardial Infarction
- Stroke Volume
- Ventricular Dysfunction, Left