A Bayesian 3-compartment model for 99mTc-MAG3 clearance.

Russell, Charles D · J Nucl Med · 2003

Level II

Where this comes from

Abstract

Because recent reports have questioned the traditional 2-compartment model for calculating tracer clearance after a single intravenous injection, a 3-compartment model was evaluated in this study. Bayesian statistics were used, which facilitated curve fitting by treating all subjects simultaneously. (99m)Tc-Mercaptoacetyltriglycine clearance data from 154 adults and 109 children were measured at several centers, typically 6-9 plasma samples spanning 5-90 min, and fitted by 2- and 3-compartment Bayesian models. Clearance estimates were found to be systematically lower for the 3-compartment model than for the 2-compartment model. A single-sample procedure based on the 3-compartment model was found to eliminate most of the known discrepancy between formulas based on single-injection and continuous-infusion reference methods. A 3-compartment model led to lower and probably more accurate clearance estimates than the conventional 2-compartment model. A new single-sample method is presented, based on the 3-compartment model as reference standard.