Diffusion MRI and spectroscopy in Rasmussen's encephalitis.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 12928965.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this study was to evaluate the diffusion MRI and proton MR spectroscopy findings in a rare disorder, Rasmussen's encephalitis. Diffusion MRI studies of 3 cases of Rasmussen's encephalitis were performed using the echo-planar trace sequence (TR=5700 ms, TE=139.03 ms). The gradient-echo diffusion sequence, PSIF (TR=21.6 ms, TE=5 ms), which is a reverse FISP sequence, and proton MR spectroscopy (TR=1500 ms, TE=40 ms) were applied in two patients. The trace sequence revealed high apparent diffusion coefficient values at the diseased regions (1.21+/-0.13 x 10(-3) mm2/s), compared with normal parenchymal values in 12 control cases (0.84+/-0.09 x 10(-3) mm2/s), indicating increased motion of water molecules (disintegration of the tissue) in these regions. The PSIF sequence revealed pixel value differences between the two hemispheres. Proton MR spectroscopy revealed decreased N-acetyl aspartate peaks, compared with five control cases.
Medical subject headings
- Diffusion Magnetic Resonance Imaging
- Encephalitis
- Magnetic Resonance Spectroscopy