Midterm results of the Ross procedure preserving the patient's aortic root.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 12970209.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Since the early 1990s, the pulmonary autograft is predominantly implanted as a freestanding root for less aortic valve regurgitation is reported. However, there is a certain risk of dilatation of the root over time potentially impairing valve function. We favor since 8 years the original subcoronary or inclusion technique to preserve the root of the patient as a restrain to dilatation. Between June 1994 and May 2002 the subcoronary (n=228) and inclusion technique (n=17) were performed in 245 patients (191 male, 54 female), mean age 45.7+/-13.4 (15-70) years. The underlying aortic valve disease was an aortic insufficiency in n=83, stenosis in n=48, a combined aortic valve disease in n=111 and an acute endocarditis in n=19 patients. Previous aortic valve surgery was performed in n=23. Last follow-up investigations (within last year) including echocardiography was performed at a mean follow-up of 29.4+/-24.7 months (553.7 patient years). Hospital mortality was n=2, late mortality n=4 (all noncardiac). Two patients were lost to follow-up (99% complete clinical follow-up). Reoperations were necessary in n=7 valves (autograft: endocarditis n=1, malpositioning n=1, leaflet prolapse n=1; homograft: stenosis n=2, insufficiency n=2). Autograft insufficiency (AI) was AI 0 in n=154, AI I n=66, AI II n=8. The maximum/mean pressure gradient across the autograft was 6.6+/-3.4 (2.1 to 25.9)/3.6+/-1.8 (1.2 to 13.2) mm Hg, respectively. Homograft insufficiency was 0 in n=167, I in n=54, II in n=9, and III in n=1. Maximum and mean transhomograft pressure gradients were 11.7+/-6.8 (2.2 to 42.6)/6.2+/-3.8 (1.2 to 24.5) mm Hg. Most patients were NYHA class I (n=214), class II (n=19), class III (n=2). Significant aortic root dilatation was not observed. Aortic valve replacement with a pulmonary autograft in the subcoronary or inclusion technique provides excellent hemodynamics with no root dilatation at least in a mid term postoperative period. Transhomograft pressure gradients are slightly increased. Longer term results with special emphasis on the pulmonary homograft are necessary.
Medical subject headings
- Aortic Valve
- Heart Valve Diseases
- Pulmonary Valve