Fatal tracheal compression after haemorrhage into the axilla.

Cook, L B; Varley, S · Br J Anaesth · 1992

case_report · Level V

Where this comes from

Abstract

We report a case of fatal ventilatory obstruction as a result of haemorrhage into the axilla after a comminuted spiral fracture of the upper one-third of the humerus. Guidelines are presented as to the early recognition of such complications and their subsequent management.