Evaluation of airway smooth muscle contractions in vitro by high-frequency ultrasonic imaging.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 1395777.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To visualize ASM contraction in vitro, we measured changes in cross-sectional area and inner circumference of isolated porcine and human bronchi in response to acetylcholine or carbamylcholine chloride (Carbachol) using high-frequency ultrasound. A mechanical ultrasonic catheter (20 MHz; diameter, 1.7 mm; echo element, 1 mm2) demonstrated three histologic layers (mucosa, cartilage and adventitia) and allowed measurement of dose-dependent contraction of porcine bronchi over time. Acetylcholine (10(-4)M) significantly decreased the cross-sectional area by 17 +/- 2.85 percent but did not change the circumference. The mean initial value for area was 0.6 +/- 0.08 cm2 and for circumference was 3.0 +/- 0.24 cm (n = 5). The EC50 of acetylcholine was 1.5 x 10(-8) M. Carbachol (10(-4)M)-induced contractions of human bronchi were also observed under the same conditions. In conclusion, high-frequency ultrasonic imaging can be used to study the morphology of ASM contractions in vitro, providing valuable information on the natural dynamics of ASM.
Medical subject headings
- Bronchi
- Muscle Contraction
- Muscle, Smooth