Displacement of an uncemented acetabular component after dislocation of a total hip prosthesis. A case report.

Laughlin, R T; Smith, K L; Adair, D M · J Arthroplasty · 1992

case_report · Level V

Where this comes from

Abstract

Review of the literature reveals few reports of complications encountered with noncemented acetabular components; most concern problems with screw or cup placement, component wear or migration, or disassembly of modular components. No reports involving the displacement of a noncemented acetabular component were found. This is a case report of a patient in whom a noncemented acetabular component was dislodged after the closed reduction of a dislocated total hip prosthesis 4.5 weeks after surgery. In light of this case, the authors believe these reductions should be performed under general anesthesia with fluoroscopic guidance. Care must be taken at surgery to ream sufficiently and obtain proper cup fit and position. Finally, the authors recommend bicortical screw fixation to provide maximum contact and rigid fixation in the early postoperative period.