A nurse-directed protocol using pulse oximetry to wean mechanically ventilated patients from toxic oxygen concentrations.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 1446498.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The usual method of weaning mechanically ventilated patients from high FIO2 in our ICU, in which housestaff ordered all ventilator changes in an unstandardized manner (control group), was compared to a nurse-directed protocol that used a single arterial blood gas (ABG) analysis and multiple pulse oximetry measurements. The protocol required an ABG to be obtained upon the initiation of intubation/mechanical ventilation, followed by pulse oximetry measurements obtained in accordance with a standardized timetable. Decreases in FIO2 were guided by these results. It was concluded that a nurse-directed oxygen weaning protocol utilizing a combination of a single ABG and multiple pulse oximetry measurements was safe, reduced the need for ABGs, and decreased the duration of patient exposure to toxic oxygen concentrations.
Medical subject headings
- Oximetry
- Positive-Pressure Respiration
- Ventilator Weaning