Posterior approach for arthroscopic reduction and antegrade fixation of avulsion fracture of the posterior cruciate ligament from the tibia with cannulated screw and washer.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 14551559.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Avulsion fracture of the posterior cruciate ligament (PCL) is a rare condition, and arthroscopically assisted reattachment of the surgical fixation of the fragment is not always an easy task. Only a few reports describe techniques for arthroscopic fixation of avulsion of the PCL.We report on a case treated arthroscopically with reduction and antegrade fixation of an avulsion fracture of the tibial attachment of the PCL with a cannulated screw and washer through an additional posterolateral portal. Postoperative morbidity was reduced, and rehabilitation was accelerated. Fixation with a cannulated screw and washer is technically simple and allows for stable fixation and immediate postoperative mobilization and pain-limited weight-bearing, even in cases of a comminuted fragment. The safe zone for an additional posterolateral portal and the technique for placing instruments and a guidewire to avoid neurovascular structures is defined.
Medical subject headings
- Arthroscopy
- Bone Screws
- Fracture Fixation, Internal
- Internal Fixators
- Posterior Cruciate Ligament
- Tibial Fractures
Anatomy
- tibia