J-tipped guidewire as a target for puncture of the subclavian artery in the placement of a reservoir port and catheter system.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 14605841.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The aim of this study was to verify the feasibility of using a J-tipped guidewire as a target for puncture of the subclavian artery in the placement of a reservoir port and catheter system (RPCS). Twenty-five patients with various hepatic malignancies underwent percutaneous implantation of an RPCS through the left subclavian artery for regional chemotherapy. To successfully puncture the left subclavian artery, a J-tipped guidewire was used as a target with fluoroscopic guidance. Technical success and complication rates, and numbers of puncture failures, were retrospectively analyzed. Implantation of the RPCS was successful in all patients. Eight (32%) patients had minor complications and no patient had major complications. The number of puncture failures per patient was 0 to 1 (mean=0.32). The J-tipped guidewire is a safe and appropriate target for puncture of the subclavian artery in the placement of an RPCS.
Medical subject headings
- Carcinoma, Hepatocellular
- Catheterization, Peripheral
- Cholangiocarcinoma
- Liver Neoplasms
- Punctures
- Subclavian Artery