Bone-preserving prosthesis with a single axis for treating osteonecrosis of the femoral head: midterm results for the thrust plate hip prosthesis.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 14648271.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We studied 27 patients (31 joints) who underwent total hip arthroplasty (THA) using the thrust plate hip prosthesis (TPP) for osteonecrosis of the femoral head. The mean follow-up period was 56 months (range 38-72 months). Clinical evaluation by the Merle d'Aubigne and Postel system showed a significant improvement from a preoperative mean score of 8.1 to a final mean follow-up score of 16.6. Mechanical loosening developed about 1 year postoperatively in one joint with a bone defect. Grade 1 stress shielding was observed in four joints. Although indications for the TPP are restricted to certain cases, unlike the conventional intramedullary stem, much can be expected of TPP. It is an outstanding prosthesis for osteonecrosis of the femoral head of young patients in terms of bone preservation and physiological load transfer.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Femur Head Necrosis
- Hip Prosthesis
Anatomy
- femur
- hip