Blood loss from arthroscopic autogenous patellar tendon anterior cruciate ligament reconstruction.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 1466703.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Thirty patients who had arthroscopically assisted autogenous patellar tendon anterior cruciate ligament reconstructions were retrospectively reviewed to determine the blood loss associated with this procedure. On average, a 1.5 U blood loss (9-point hematocrit decrease) occurred with this procedure. The amount of blood lost was not affected by use of an intraoperative tourniquet. Blood loss was minimally increased by extra-articular iliotibial band surgery and was unrelated to surgical timing, in the acute versus chronic phase of the injury.
Medical subject headings
- Anterior Cruciate Ligament
- Arthroscopy
- Blood Loss, Surgical
Anatomy
- knee