Accurate template-based correction of brain MRI intensity distortion with application to dementia and aging.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 14719691.
- Also identified by PMC identifier 2291516.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This paper examines an alternative approach to separating magnetic resonance imaging (MRI) intensity inhomogeneity from underlying tissue-intensity structure using a direct template-based paradigm. This permits the explicit spatial modeling of subtle intensity variations present in normal anatomy which may confound common retrospective correction techniques using criteria derived from a global intensity model. A fine-scale entropy driven spatial normalisation procedure is employed to map intensity distorted MR images to a tissue reference template. This allows a direct estimation of the relative bias field between template and subject MR images, from the ratio of their low-pass filtered intensity values. A tissue template for an aging individual is constructed and used to correct distortion in a set of data acquired as part of a study on dementia. A careful validation based on manual segmentation and correction of nine datasets with a range of anatomies and distortion levels is carried out. This reveals a consistent improvement in the removal of global intensity variation in terms of the agreement with a global manual bias estimate, and in the reduction in the coefficient of intensity variation in manually delineated regions of white matter.
Medical subject headings
- Algorithms
- Alzheimer Disease
- Brain
- Image Interpretation, Computer-Assisted
- Imaging, Three-Dimensional
- Magnetic Resonance Imaging
- Models, Biological
- Subtraction Technique