Early trans-tibial oedema control using polymer gel socks.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 14727703.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The aim of this investigation was to determine if early trans-tibial oedema control, by polymer gel socks prior to the fitting of a shrinker, could enhance trans-tibial stump volume reduction. Sixteen (16) adults, following unilateral trans-tibial amputation, were randomly allocated into 2 groups and baseline volume measurements taken of their stumps. The control group followed the normal removable rigid dressing programme, while the experimental group wore a polymer gel sock in conjunction with the removable rigid dressing. When wound healing permitted fitting of a shrinker, use of the polymer sock was discontinued and a stump volume measurement was taken. The shrinker was worn for a minimum of 2 days before casting for a prosthesis and a final stump volume measurement taken. Volumes were measured by water filling casts taken of the stump and calculated as a percentage of the baseline volume and the rate of volume reduction calculated. Two t-tests for unequal variance (2-tail, alpha=0.05) were used to compare the rate of percentage volume reduction between the groups, for the trial period of baseline to shrinker fitting and baseline to casting. A statistical difference was observed for the period of baseline to shrinker exceeding the 95% confidence limit (p<0.05). No significant difference was detected for the overall period of baseline to cast. It was concluded that early oedema control by polymer gel sock could enhance stump volume reduction, prior to a shrinker. It was also found that no volume advantage was carried over to the time of casting for a prosthesis.
Medical subject headings
- Amputation Stumps
- Artificial Limbs
- Bandages
- Edema
Anatomy
- tibia