Laparoscopic surgery in a patient with ventriculoperitoneal shunt: monitoring of shunt function with transcranial Doppler.

Ravaoherisoa, J; Meyer, P; Afriat, R; Meyer, Y; Sauvanet, E; Tricot, A; Carli, P · Br J Anaesth · 2004

case_report · Level V

Where this comes from

Abstract

We describe the use of transcranial Doppler (TCD) monitoring during laparoscopic resection of an ovarian cyst in a young woman who previously underwent ventriculoperitoneal shunting for hydrocephalus. Shunt function was not altered by pneumoperitoneum, except during transient episodes of high intra-abdominal pressure. The role of TCD monitoring during laparoscopic procedures in patients with cerebrospinal fluid shunt is discussed.