MRI of slow flow in artificial duct in swine.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 14767600.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Our aim was to evaluate whether it is possible to visualize slow flow within a small catheter placed inside a living animal. We used a flow-sensitive, single-shot turbo spin-echo (SS-TSE) MRI sequence, developed in house, based on diffusion-weighted (DW) techniques. Four anesthetized pigs were used as models. A plastic catheter was surgically placed within the common bile duct (CBD). To mimic flow, the catheter was filled with Ringer's acetate and connected to a pump. b factors (s/m(2)) of 0, 6, and 12, with flow velocities raging from 0 to 1.32 cm/s, were used. A total of 375 images were obtained and examined. After correction for bowel movement artifacts, all images displayed the catheter on zero flow. With a flow of 0.66 cm/s or higher, no images displayed the catheter with a b factor of 6 or 12. On the slower flow velocities, it was variable whether the catheter was visible or not, but at b=6 and flow 0.17 cm/s all catheters were viewable. This method made it possible to perform a semiquantitative evaluation of flow velocities in vivo, dividing flow into three groups.
Medical subject headings
- Cholangiopancreatography, Magnetic Resonance
- Common Bile Duct
- Diffusion Magnetic Resonance Imaging
- Image Processing, Computer-Assisted
- Manometry
- Pancreatic Ducts