Does septal-lateral annular cinching work for chronic ischemic mitral regurgitation?
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 15001893.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Ring annuloplasty, the current treatment of choice for chronic ischemic mitral regurgitation, abolishes dynamic annular motion and immobilizes the posterior leaflet. In a model of chronic ischemic mitral regurgitation, we tested septal-lateral annular cinching aimed at maintaining normal annular and leaflet dynamics. Twenty-five sheep had radiopaque markers placed on the mitral annulus and anterior and posterior mitral leaflets. A transannular suture was anchored to the midseptal mitral annulus and externalized through the midlateral mitral annulus. After 7 days, biplane cinefluoroscopy provided 3-dimensional marker data (baseline) prior to creating inferior myocardial infarction by snare occlusion of obtuse marginal branches. After 7 weeks, the 9 animals that developed chronic ischemic mitral regurgitation were restudied before and after septal-lateral annular cinching. Anterior and posterior mitral leaflet angular excursion and annular septal-lateral and commissure-commissure dimensions and percent shortening were computed. Septal-lateral annular cinching reduced septal-lateral dimension (baseline: 3.0 +/- 0.2; chronic ischemic mitral regurgitation: 3.5 +/- 0.4 [P <.05 vs baseline by repeated measures analysis of variance and Dunnett's test]; septal-lateral annular cinching: 2.4 +/- 0.3 cm; maximum dimension) and eliminated chronic ischemic mitral regurgitation (baseline: 0.6 +/- 0.5; chronic ischemic mitral regurgitation: 2.3 +/- 1.0 [P <.05 vs baseline by repeated measures analysis of variance and Dunnett's test]; septal-lateral annular cinching: 0.6 +/- 0.6; mitral regurgitation grade [0 to 4+]) but did not alter dynamic annular shortening (baseline: 7 +/- 3; chronic ischemic mitral regurgitation: 10 +/- 5; septal-lateral annular cinching: 6 +/- 2, percent septal-lateral shortening) or posterior mitral leaflet excursion (baseline: 46 degrees +/- 8 degrees; chronic ischemic mitral regurgitation: 41 degrees +/- 13 degrees; septal-lateral annular cinching: 46 degrees +/- 8 degrees ). In this model, septal-lateral annular cinching decreased chronic ischemic mitral regurgitation, reduced annular septal-lateral diameter (but not commissure-commissure diameter), and maintained normal annular and leaflet dynamics. These findings provide additional insight into the treatment of chronic ischemic mitral regurgitation.
Medical subject headings
- Mitral Valve
- Mitral Valve Insufficiency
- Myocardial Ischemia