Effects of resin formulation and nanofiller surface treatment on the properties of experimental hybrid resin composite.

Musanje, Lawrence; Ferracane, Jack L · Biomaterials · 2004

biomechanical · Level V

Where this comes from

Abstract

This study evaluated the effects of nanofiller surface treatment and resin viscosity on the early and long-term properties of experimental hybrid composites. Three resin formulations (low, medium and high viscosity) were prepared by varying the ratio of TEGDMA:UDMA:bis-GMA (47:33:16 wt%; 30:33:33 wt%; 12:33:51 wt%). Composites contained 71.3 wt% silanated strontium glass (1-3 microm) and 12.6 wt% of either silanated or unsilanated silica (OX-50; 0.04 microm). Specimens (n=10) for flexural strength, flexural modulus, fracture toughness and Knoop hardness were tested after 24 h, 1 and 6 months exposure to water at 37 degrees C. Degree of conversion (DC) was determined 24 h after photoinitiation using FTIR. Resin viscosity only had a marginal influence on the mechanical response of composites but it can be adjusted to achieve a balance between DC and mechanical properties. Adding non-bonded nanofiller to hybrid composites had no systematic effect on DC. Non-bonded nanofillers had no significant effect on the long-term properties of hybrid composites.

Medical subject headings