In the present in vitro study, osteoblast (bone-forming cells) viability and cell density were investigated when cultured in the presence of nanophase compared to conventional (i.e. micron) alumina and titania particles at various concentrations (from 10,000 to 100 microg/ml of cell culture media) for up to 6h. Results confirmed previous studies of the detrimental influences of all ceramic particulates on osteoblast viability and cell densities. For the first time, however, results provided evidence of increased apoptotic cell death when cultured in the presence of conventional compared to nanophase alumina and titania particles. Moreover, since material characterization studies revealed that the only difference between respective ceramic particles was nanometer- and conventional-dimensions (specifically, phase and chemical properties were similar between respective nanophase and conventional alumina as well as titania particles), these results indicated that osteoblast viability and densities were influenced solely by particle size. Such nanometer particulate wear debris may result from friction between articulating components of orthopedic implants composed of novel nanophase ceramic materials. Results of a less detrimental effect of nanometer--as compared to conventional-dimensioned particles on the functions of osteoblasts provide additional evidence that nanophase ceramics may become the next generation of bone prosthetic materials with increased efficacy and, thus, deserve further testing.
Medical subject headings
- Aluminum Oxide
- Nanotubes
- Osteoblasts
- Tissue Engineering
- Titanium