This study evaluates the safety and outcome of a minimally invasive technique for inserting a standard dynamic hip screw for intertrochanteric fractures. The use of standard plate in a minimally invasive technique is both possible and advantageous to patient outcome. Prospective surgeon-randomized blinded outcome clinical study comparing new technique to conventional technique. Pain, operative time and mean hemoglobin drop in percutaneous hip fixation. The minimally invasive technique had significantly less blood loss (P < 0.001), operative time (P < 0.001) and a trend to less morphine use. Minimal invasive technique significantly reduces blood loss and operative time for fixation of intertrochanteric hip fractures without sacrifice of fixation stability or bone healing.
Medical subject headings
- Fracture Fixation, Internal
- Hip Fractures
Anatomy
- hip