Management of aortic cannulation site blowouts.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 1510537.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
An alternative technique of handling the aortic cannulation site blowout is described. The cannulation site is excluded with a side-biting clamp. The area is excised. Pericardial patch is sewn in to cover the defect.