Abstract
The clinical outcomes of posterior cruciate ligament reconstruction are varied. No previous studies have investigated the effect of graft length on the structural properties of the graft. Graft length significantly affects the structural properties of posterior cruciate ligament grafts. Controlled laboratory study. Eight Achilles tendon grafts were tested under tensile loads up to 400 N at 3 different lengths: long (75 mm), medium (48 mm), and short (34 mm). These 3 lengths represent midtunnel fixation, inlay fixation, and fixation near the ligament insertions. Shortening the graft from both long to medium and from medium to short increased the stiffness by approximately 25%. Long and medium grafts displaced significantly more than medium and short grafts, respectively. The effective length of a graft, which is determined by where it is fixed, should be considered an important variable in posterior cruciate ligament reconstruction.
Medical subject headings
- Achilles Tendon
- Posterior Cruciate Ligament