The Oxford unicompartmental knee prosthesis: a 2-14 year follow-up.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 15168007.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Our medium- and long-term results obtained with the Oxford unicompartmental knee prosthesis for unicompartmental knee osteoarthrosis are presented. Ninety-seven prostheses were evaluated (87 medial, 10 lateral) in 86 patients, with the Hospital for Special Surgery knee score after 2-14 years (mean follow-up: 6 years 9 months). Five prostheses were lost to follow-up. Eight patients died, not related to surgery; none had undergone a revision. Fourteen revisions (of which one bilateral UKP), 11 medial and three lateral, were performed. The mean HSS score of the 69 UKPs was 178.8 (80% excellent, 10% good, 4% fair, 6% poor). These findings confirm the good results reported in other studies, regarding proper patient selection and a consistent operative technique.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Osteoarthritis, Knee
Anatomy
- knee