Histologic reactions to particulate wear debris in different mesenchymal tissues: studies on the nonreplaced compartment from revised uni-knees.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 15188108.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The interface between bone and artificial-joint implants consists of soft tissue. This tissue varies from fibrocartilage to loose fibrous tissue. Tissues that resemble those can be found in normal joints. Sixteen knees with unicompartmental knee prostheses, revised because of excessive wear of the tibial insert, were studied. Synovium, synovial fluid, cartilage, and bone from the nonreplaced compartment were studied with light microscopy. We found wear particles and reactions to those in all tissues except cartilage. In the subchondral bone, we found osteolytic-like processes undermining the cartilage peripherally. Our conclusion from these findings is that the histologic composition of the bone-implant interface might be an important factor regarding the reaction of the tissue to wear particles and, thus, component fixation.
Medical subject headings
- Foreign-Body Reaction
- Knee Prosthesis
- Osteolysis
- Prosthesis Failure
Anatomy
- knee