Surgical management of polyethylene wear and pelvic osteolysis with modular uncemented acetabular components.
review · Level V
Where this comes from
- Record sourced from PubMed, PMID 15190567.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Osteolysis, usually associated with polyethylene wear, has become one of the most prevalent complications associated with total hip arthroplasty inserted without cement. Management of osteolysis is challenging because the disorder tends to develop silently and surgical intervention can result in complications. In addition, long-term outcomes are unknown. We discuss the current knowledge and data available on polyethylene wear and pelvic osteolysis with modular uncemented acetabular components. We also outline an algorithm for evaluation and treatment of patients. In general, we see patients with well-fixed components every 2 years, and we base follow-up visits after 6 years on predicted polyethylene wear rates and the presence or absence of pelvic osteolysis.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Biocompatible Materials
- Osteolysis
- Polyethylene
- Prosthesis Failure
Anatomy
- hip
- pelvis